If the code returns for error E25
If E25 returns after an accessible check, do not keep resetting the appliance. Record when it appears, stop at any unsafe condition, and use the model-specific service path.
Safe sequence
- 1Disconnect power and wear cut-resistant gloves because glass may be present.
- 2Remove the filter and inspect the user-accessible pump cover using the model manual.
- 3Remove visible foreign objects and lock the cover and filter back in place.
Stop and get qualified help when
- Sharp debris cannot be removed safely
- The impeller is damaged or the code returns